Data sheet pressure switch and thermostat kp and kpi. View and download danfoss mp 54 installation manual online. Also please note for the psu equivalents do not come with relief valves, these have to be ordered. Kp pressure switches danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. After operational stop, these units reset automatically.
Installation guide pressure switch kp 1, kp 2, kp 5. Acb cartridge pressure switch is a small disc type pressure switch for use in refrigeration and. The pressure switches are tted with singlepole changeover switch spdt. Pressure switches with manual reset set the cutout presure on the cutout scale range scale.
Kp pressure switches are recommended for gaseous media also water, but only when mounted directly on the pipe do not use capillary tube mounting. Do not use screwdriver to resume control operation after safety cutout, push reset knob as indicated. Because they play an important safety role in these applications, its crucial that the automatic or manual reset functions operate perfectly so reliability and quality are paramount. Danfoss kp35 pressure switches, regulate and monitor the pressure in. They provide automatic or manual reset limit protection.
The pressure switches are fitted with singlepole changeover switch spdt. I can find the high pressure manual resets for r22410a but i can only find auto reset for the low pressure switches. Low water pressure cutout switch square d m4 pressure switch w low pressure cutoff. They provide automatic limit protection or manual reset limit protection for pressure systems. Data sheet pressure switch and thermostat kp and kpi ic. Pressure switches danfoss kp15 highlow pressure with automanual reset switch danfoss kp15 highlow pressure with automanual reset switch product code. Kp15 models are dual switches fitted with an extra contact to give an independent lowpressure trip signal. Rt30aw pressure switch for rising pressure g12, ip66, auto reset. How to calibrate and adjust a pressure switch learning. Manual reset for pressure limiters possible only by means.
Very competitive prices, fast delivery time and professional technical support. Manual reset units with manual reset can only be restored to operational. The position of the switch is determined by the pressure switch setting and the pressure at the connector. The rt pressure switches series consist of a variety of ordinary controls including differential and neutral zone pressure controls, safety pressure controls for steam boiler plant, and gold plated failsafe controls for applications in which safety or economical consequences are critical factors. Pressure switch, kp34, 3 psig differential, manual reset, 1418 npt, kp series. Manual reset is possible to operate only after return of pressure. The starting and stopping of a well water pump is typically controlled by a pressure switch similar to the one shown below. Danfoss kp15 highlow pressure with auto manual reset switch product code. With an automatic reset dwk version, it is always possible for the system to be switched on again automatically after the pressure decreases by a. Pressure switch, differential pressure switch, type rt danfoss.
Data sheet cartridge pressure switch type cb pressure controls cb series are compact disc type pressure switches with fixed setpoints for longstanding use in refrigeration and air conditioning systems. Danfoss pressure switches are electromechanical controls and limiters, that control the pressure of air and liquids within a given pressure range. Units with manual reset can only be reset during operation by activation of the reset button. Danfoss electrical pressure switches for sale ebay. Jun 11, 2010 pro refrigeration, incs technical support demonstrates how to adjust an danfoss dual pressure control. Pressure switches, type kp technical leafl et industrial automation ic.
Kp pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. Data sheet pressure switch, kpu set point a predetermined value to which a switch is adjusted and at which it performs its intended function. Kp5 models are single high pressure switches with changeover contacts. Kp15 models are dual switches fitted with an extra contact to give an independent low pressure trip signal. Restart pressure is equal to cutout pressure minus differential value. Click on the hyperlinks below to see pressure switch videos on the rc worst youtube channel. Data sheet pressure switch, type kp terminology reset 1. Danfoss kp35 pressure switches, regulate and monitor the pressure in air, marine, water and heating applications. Kp pressure switches are available in ip30, ip44 and ip55 enclosures.
The deadband or reset or switching differential is the difference in the rising and falling pressures at which the pressure switch operates. Manual reset a unit with manual reset can only be restored to operational mode by activation of the external reset button. Danfoss highlow pressure switch with adjustable reset kp series kp1 0601103 lp manual. Data sheet pressure switch, type kp danfoss dcs mn 2016. Make offer new danfoss pressure controller switch rt 110. Low prices, fast delivery time and professional technical support.
R1 r124 r4a r22 r404a r407a r407c r407f r407h r422b r422d r438a r448a r449a r450a r452a r507a r5a r449b r515b. The kp series are suitable for gaseous media and air. The ashcroft b4 pressure switch may be used on virtually all industrial and oem applications. The 060214466 provide automatic limit protection or manual reset limit protection for pressure systems.
How to install a danfoss 6070 series thermostat duration. Pressure limiters can be manually reset by pressing reset button when the pressure is equal to the cutout pressure minus fixed value of the differential. Automatic reset a unit with automatic reset is restored to operational mode automatically data sheet pressure switch. View and download danfoss kp 15 installation manual online. Danfoss highlow automanual reset switch pressure controls. Danfoss kp15 highlow pressure with automanual reset switch.
Installed new hp switch set for 375 psig checked amp draw on condensing fans both working and correct rotation rated at 2. Jun 03, 2016 a hands on demonstration of how to adjust a pressure switch for commercial refrigeration. Danfoss rt pressure switch pressostat cse distributors. C pressure switch additive the c437d,e series 2000 gas pressure switches are pressureactuated switching devices used in industrial gas system applications for safety shutoff, pressure control, and differentialpressure control. The bcp type is a series of dedicated pressure switches for. The difference between pressure cutout and pressure cutin. Kp pressure switches danfoss kp switches are used for regulating, monitoring and alarm systems in. If you continue, you will be logged in and forwarded to your default danfoss store. Ip55 to en 60529 iec 60529 ip55 is obtained when the kp pressure switches. Danfoss kp kpi pressure switches are designed for gaseous and liquid media some types are ul, csa and fm approved.
Import data and price of danfoss under hs code 8536 zauba. For high pressure switches the restart pressure is equal to cutout pressure minus differential. Rt110 new old stock 10d52 rt110 new old stock 10d52 danfoss kps 45 pressure switch 0603121 105. Industrial pressure switches pressure controls danfoss. So the pressure switch must be manually reset by the user to enable restart of the equipment. Units with manual reset can only be reset during operation by activation. The rt single pressure switches series consist of a variety of ordinary controls including neutral zone pressure switches, safety pressure switches for steam boiler plant, and gold plated failsafe controls for applications in which safety or economical consequences are. If you are looking for danfoss usa product store and catalog which enables you to purchase our products then please select the usa product store button. Danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. Rt121 0175156666 pressure switches are used in general industrial and marine sectors.
Danfoss bcp pressure controller danfoss distributors. Acb cartridge pressure switch is a small disc type pressure switch for use in refrigeration and air conditioning systems. Manual reset a unit with manual reset can only be restored to operational mode by activating the external reset button. Kp pressure switch commercial refrigeration danfoss. C437e2002 honeywell c437e2002 manual reset, 1 to 26 w. Danfoss kp15 highlow pressure manual auto reset switch product code. The switch is preset with both the cuton and cutoff pressure. Automatic reset a unit with automatic reset is restored to. Data sheet cartridge pressure switch type acb and ccb pressure controls acb and ccb are compact disc type pressure switches with fixed setpoints for longstanding use in refrigeration and air conditioning systems. Danfoss kp pressure switches are used for regulating, monitoring and alarm systems in industrial applications. For kp pressure switches with manual reset, the top cover must be separately ordered code no. Can be used with steam, air, gaseous and liquid media. Danfoss dual high pressure switch kp7bs with manual reset for.
Pressure switch type kp refrigeration and air conditioning danfoss. The kp pressure switches can be used as safety switches. Kp5 models are single highpressure switches with changeover contacts. Pressure switches displaying products 1 12 of 17 switch to grid view. Danfoss 060214966 kp 34 auto reset pressure switch danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. Manual reset the manual reset mechanism does not allow the pressure switch to automatically reset after the switch has cut out. Pressure switch kp 15, kp 17w, kp 17b, kp 25 danfoss. Kp pressure switches with auto reset are supplied with top cover. Danfoss kp series pressure switches for light industry. Danfoss dual high pressure switch kp7bs with manual reset.
Switches for commercial refrigeration pressure switch. Set point a predetermined value to which a switch is adjusted and at which it performs its intended function. Rt116 017520366 pressure switches are used in general industrial and marine sectors. Kp kpi pressure switches offer a compact, robust design, and proven repeatable performance. Set the cutout pressure on cutout scale range scale. They are fitted with a singlepole switch changeover spdt, and can control singlephase ac motors of up to 2 kw directly. Pressure switches with manual reset set the cutout pressure on the range scale. How to adjust a pressure switchjdnel refrigeration youtube. Danfoss kp15 highlow pressure with automanual reset switch product code. We offer low prices, fast delivery time and professional technical support. Cs pressure switches have a threepole switch and adjustable differential.
Switches for commercial refrigeration pressure switch danfoss. Single setpoint, fixed deadband, spdt or single setpoint, fixed deadband, 2 spdt dpdt action vacuum thru 3000 psi. The plugandplay, din 43650acompliant electrical connections on top of the pressure controls meet the industry requirements. The cuton pressure is the low pressure that starts the pump and the cutoff pressure is the high pressure that turns off the. Danfoss rt pressure switches pressostat are used in general industrial and marine sectors. Danfoss 060214866 kp34 manual reset pressure switch note. High pressure safety controls for this purpose are classified into three types. This is a setting that determines the amount of pressure change required to reset the switch to its normal state after it has tripped. Danfoss kpi pressure switches are used for regulating, monitoring and. Danfoss highlow pressure switch with adjustable reset kp series kp2 0601120 lpauto. View and download danfoss rt 112 installation manual online. The latest equivalent by danfoss of the ps and psu is the cs pressure switch, please note the ranges are not the same so below we have offered an alternative nearest to the old settings, please click on the link to see the new ranges. The bcps innovative features include failsafe bellows, manual or automatic reset options, and an spdt contact system based on a micro switch. Pressure switches and thermostats, type kp danfoss.
451 888 148 609 1411 801 231 863 1139 1164 848 131 758 654 192 243 472 1437 730 781 313 1345 1152 1037 674 360 145 933 8 1177 231 790 209 872 324 114 161 188 816 654 1259 956 979